FAQ Category: The load decreases with the maneuver in the neutral position

When the engine is switched off

Cause 1: The load-holding valve setting has been disturbed. Pollution in the valve may have caused the leakage. Adjust the load holding valve, see chapter “7 Adjustment instructions” – Adjustment instructions for hydraulic valves. If this does not help, remove the valve and clean the details carefully. Mount and adjust according to the instructions. If …

When the engine is switched off Läs mer »